ISO 7368:2016 pdf free download.Hydraulic fluid power – Two-port slip-in cartridge valves – Cavities.
1 Scope
ISO 7368 specifics only geometrical data relating to cavities in which two-port hydraulic slip-In cartridge valves are mounted in order to ensure interchangeability.
NorK For esample. ISO 7368 does not specify rated pressures.
It applIes to cavities [or two-port hydraulic slip-In cartridge valves which are generally applicable to
Industrial equipment.
2 Normative references
The following documents are referred to in the test in such a way that some or all of their content constitutes requirements of ISO 7368. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (Indudlng any amendments) applIes.
ISO 1302. Geometrical Product Specifications (GPS) — Indication of surface texture In technical product documentation
ISO 2768-1. General tolerances — Port 1: Tolerances for linear and angular dimensions wititout indMdual tolerance Indications
ISO 3601-2. Fluid power systems — 0-rings — Part 2: Housing dimensions for general applications
ISO 42H7. Geometrical Product Specifications (GPS) — Surface texture: Profile method — Terms, definitions
and surface texture Parameters
3 Terms and deflnitions
For the purposes of ISO 7368, the terms and definitions given In ISO 5598 apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
5) Z1: supplementary pilot, inlet:
6) Zi: supplementary pilot, return;
b) F1 … F12 Identify threaded holes for fixing screws; r) 6, Gi and G2 identify the location of pin holes;
d) D Identifies the fixing screw diameter;
e) rmas identifies the mounting surface edge radius;
F) R indicates the maximum radius at the bottom oldj. The code system used in ISO 7368 is defined in ISO 5783. NOTE Size 15 and size 16 are not yet listed in ISO 5783
S Tolerances
The following requirements shall be applied to the sealing and chamfer surfaces. i.e. that area within the chain lines:
— surface roughness (see ISO 3601-2);
— surface roughness, Rz as indicated on the figures according to ISO 1302 and ISO 4287;
— all non-specified surface finishes: Ks 63;
— surface roughness values are given in micrometres (nm);
— surface flatness: 0.01 mm over a distance of 100mm (see ISO 3601-2).
The following tolerances shall be complied with along the x,y and z axes with respect to the origin:
— pin holes ±0,2 mm;
— screw holes: ±0,2 mm;
— port holes: ±0,2 mm:
— general tolerances according to ISO 2768-1 for linear and angular dimensions without tolerances.
As for other dimensions, see Fignr1 to Figurej.6.
6 Dimensions
6.1 CavIty dimensions for hydraulic slip-In cartridge valves with tw main ports shall be selected from Figure ito FIgure 16 and Table ito Table 16 as specified in 62 to 6J1.
6.2 Cavity dimensions for all types of valves, escept main system pressure-relief valves, with main ports oF 16 mm nominal diameter (sIze 06) (code 7368 – 06. 1 . 1 – 16) are specified in Table 1 and shown In Figure 1.
6.3 Cavity dimensions for main system pressure-relief valves with main ports 0116 mm nominal diameter (sIze 06) (code 7368.06.2. 1 – 16) are specified In Table 2 and shown In Figure 2.
6.4 Cavity dimensions for all types of valves, escept main system pressure-relief valves, with main ports of 25 mm nominal diameter (sIze 08) (code 7368 – 08- 3- 1 – 16) are specified In Table 3 and shown In FIgure 3,
6.5 Cavity dimensions For main system pressure-relirl valves with main ports of 25 mm nominal diameter (size 08) (code 7368.08-4- 1 – 16) are specified in Table 4 and shown in hgut4.
6.6 Cavity dimensions for all types of valves, except main system pressure-relief valves, with main ports of 32 mm nominal diameter (size 09) (code 7368- 09- S – 1 – 16) are specified In Tahia and shown in Eigure.,
6.7 CavIty dimensions for main system pressure-relief valves with main ports of 32 mm nominal diameter (size 09) (code 7368 -09-6- 1 – 16) are specified in Tahjcb and shown in fAgure6
6.8 Cavity dimensions for all types of valves, except main system pressure-relief valves, with main ports of 40 mm nominal diameter (size 10) (code 7368- 10 – 7- 1 – 16) are specified in Table 7 and shown in Figure 7.
6.9 CavIty dimensions for main system pressure-relief valves with main ports of 40 mm nominal diameter (size 10) (code 7368 – 10-8- 1 – 16) are specified in Table Band shown In Figure 8.
6.10 CavIty dimensions for all types of valves, except main system pressure-relief valves, with main ports of 50 mm nominal diameter (sIze 11) (code 7368. 11 -9 – 1 – 16) are specified In Table 9 and shown in Figure 9.
6.11 Cavity dimensions for main system pressure-relief valves with main ports of 50 mm nominal diameter (size 11) (code 7368 – 11 – 10- 1 – 16) are specified In Table 10 and shown In Figure 10.
6,12 Cavity dimensions for all types of valves, except main system pressure-relief valves, with main ports of 63mm nomInal dLameter (size 12) (code 7368. 12- 11- 1 – 16) are specified in Table 11 and shown in Figure 11.
6.13 Cavity dimensions for main system pressure-relief valves with main ports of 63 mm nominal diameter (size 12) (code 7368 – 12. 12- 1 . 16) are specified In Table 12 and shown In Figure 12.
614 CavIty dimensions for all types of valves, except main system pressure-relief valves, with main ports of 80 mm nominal diameter (sIze 13) (code 7368- 13- 13. 1 – 16) are specified In Table 13 and shown in FIgure 13.
6.15 Cavity dimensions for all types of valves, except main system pressure-relief valves, with main ports of 100 mm nominal diameter (sIze 14) (code 7368- 14 – 14- 1- 16) are specified In Table 14 and shown in Elgurej.4.
6.16 CavIty dimensions for all types of valves, except main system pressure-relief valves, with main ports of 125 mm nominal diameter (size 15) (code 7368 – 15- iS- 1- 16) are specified In Table 15 and shown in Figure 15.
6i7 Cavity dimensions for all types of valves, except main system pressure-relief valves, with main ports of 160 mm nominal diameter (size 16) (code 7368. 16 – 16- 1 – 16) are specified In Table 16 and shown In F1greJ.6.
7 Identification statement (Reference of ISO 7368)
Use the following statement in test reports, catalogues and sales literature when electing to comply with ISO 7368:
Cavlty dimensions conform to ISO 7368, Hydraulic fluid power — Two-port slip-In cartridge valves — Cavities.
ISO 7368:2016 pdf free download